sanyo CBP2572 ED1 Repair Tips
Search: CBP2572 ED1 sanyo
Results 10
Results 10
Make | Model Ch. | Symptom | Problem Solution | Solution | By: |
---|---|---|---|---|---|
Sanyo | CBP2572 ED1 | WHITE DOT PATTERN | DTI2223-06 , ON DIGITAL PCB | ||
Sanyo | CBP2572 ED1 | To reprog NVM memory chips | Press service button (thro' hole in set front) & VOL+ together - be careful - all previous data will be lost! | ||
Sanyo | CBP2572 ED1 | STRANGE E/W FAULT | CHECK DPU2553/75 ON DIGI BOARD | ||
Sanyo | CBP2572 ED1 | Q903 s/c R301 ( 3R9 ) o/c | Check R3165 D/J and TEA2260 | ||
Sanyo | CBP2572 ED1 | Int loss off air signals | Q173 D/J | ||
Sanyo | CBP2572 ED1 | EW faulty | DPU2553/75 deflection proc chip | ||
Sanyo | CBP2572 ED1 | Dead | R301 3R9 15w surge res o/c, Q303 2SC4429 chopper tr s/c, R315 dry joints caused it-also IC301 TEA2260 faulty | ||
Sanyo | CBP2572 ED1 | Dark & lacking contrast | Unable to get "OK" indication when adj A1 volts in service mode. IC501 VCU2136 on digital pcb faulty - pt no 409 212 0608 | ||
Sanyo | CBP2572 ED1 | Blank raster, no sound or OSD | 2 x NVM chips on sigs panel sus; can be replaced or reprog | ||
Sanyo | CBP2572 ED1 | BLANK RASTER NO SOUND NO ON SCREEN DISPLAYS . MEMO | REPLACE OR TRY RE-PROGGRAMMING BY PRESSING THE SERVICE SWITCH AND VOLUME PLUS BUTTON TOGETHER . SERVICE SWITCH BEHIND SMALL H |